Research Report Library > Reports
Report
L51621 Hydrogen-Related Failures at Mechanically Damaged Regions
Abstract
Leaks attributed to hydrogen-stress cracking (HSC) initiating in regions of mild mechanical damage have been reported in cathodically protected pipe lines constructed from high-strength, microalloyed, controlled-rolled steels. The hydrogen is believed to be present in service from the cathodic potential applied. Laboratory studies were initiated to determine the factors that contributed to those unexpected failures. Strain aging at ambient temperatures as a result of deformation introduced during the mechanical damage, was found to be a significant factor. Smooth-bar specimens that were strained and then aged failed by HSC within one week, whereas specimens that were not strain aged did not fail by HSC. Result: The findings of this research indicate a potential sequence of events which may lead to hydrogen-related failures in regions of mild mechanical damage: (1) Following the damage, ambient-temperature strain aging which promotes sensitivity to HSC takes place in the mechanically damaged region, in a surface layer of the pipe wall which has been subjected to a critical level of strain. The time period for this step would be on the order of several years. (2) Electrochemical conditions which promote hydrogen charging develop at the pipe surface from the cathodic current applied (or possibly corrosion). (3) Local stresses in the mechanically damaged region are elevated above the threshold stress for HSC by the moderate stress concentration provided by the mechanical damage. For the X70 pipe studied, the stress elevation should be at least 20 percent above the nominal hoop stress. (4) An HSC crack initiates and grows in the strain-aged surface layer. (5) The crack propagates further by HSC, through the non-strain-aged portion of the wall, as a result of the high stress concentration at the crack tip. (6) When the crack grows to a critical depth, it propagates rapidly through the wall by overload and causes a leak.
Digital Access
After purchase, you will receive a download link to the report you purchased. Please confirm the email address you use to purchase the report is the email address you would like to receive the report.
If you have any trouble receiving the download instructions, please first check any spam or junk folders. Reach out to support if you need further assistance.
L51621 Hydrogen-Related Failures at Mechanically Damaged Regions
Quantity
Digital products are limited to 1 per purchase
List Price
$349
Member Price
$0
Members will be redirected to a member-only report database for access to all reports. You must have a login to access reports for free.
